VELUX Modular Skylight – Wall-mounted Longlight 5°– 45°
Connect different building heights and add daylight to rooms
Wall-mounted Longlights (5°– 45°) allow different ceiling heights to be the joined and simultaneously lets daylight and fresh air into the rooms below it. When installed at up to 45°, the Wall-mounted Longlights add vertical space to the room.
Wall-mounted Longlights can be mounted between a flat or sloped roof as the base and a vertical wall.
We make the sub-constructions needed for installation and also offer a complete fitting service together with the VMS modules by the GLASOLUX installation team.
Values | |
---|---|
Uw value (double): | up to 0.5 W (m2/K) |
Ug value (double): | up to 0.86 W (m2/K) |
Water resistance: | Class E1200, EN 12208: 2000 |
Minimum dimensions required | |
---|---|
Module width: | 675 – 1000 mm |
Module height: | 600 – 3000 mm |
Roof opening width for fixed modules: | 600 – 3200 mm |
Roof opening width for opening modules: | 800 – 2600 mm |
Installation angle of the skylight system: | 5°– 45° |
Opening casement: | |
---|---|
Modules: | alternate modules can be opened by an integrated chain actuator |
Ventilation module: | The ventilation module opens up to 410 mm. Ventilation can be opened by an integrated chain actuator. |
Smoke venting module: | The smoke venting module opens up to 700 mm in under 60 seconds. Smoke venting can only be controlled by a building management system. |
Please note: | Electrically operated venting modules have a recommended minimum installation height of 2.5 m above floor. If installed with less than 2.5 m clearance, appropriate safety measures must be applied by the installer/user to prevent serious injury. |
Double- or triple-glazed insulating glass
- Insulating glass (Ug values up to 0.5 W (m2/K))
- Tempered outer pane
- Laminated safety glass on the inner side
- Protection against falling glass
- Sound insulation (traffic, rain and hail)
- “Warm edge” spacer (protects insulation performance over time and minimises the risk of condensation on the edges of the pane)
- Step glass (drains water away from the pane)
- Solar control coating (optional)